01
Sizing
A room-by-room heat loss calculation decides the output the heat pump needs. Too small and it struggles in cold weather; too large and it keeps switching on and off. We size from the building, not from the label on the old boiler.
Service 02
An air-to-water heat pump takes heat from the outside air and passes it to the water in your heating system. It works best when it is sized carefully and paired with emitters that suit lower water temperatures, and that is where most of our effort goes.
What is included
The outdoor unit is the visible part. Most of what decides whether the system is comfortable happens in the calculation and in the pipework.
01
A room-by-room heat loss calculation decides the output the heat pump needs. Too small and it struggles in cold weather; too large and it keeps switching on and off. We size from the building, not from the label on the old boiler.
02
Heat pumps run at lower water temperatures than most boilers. We check every radiator and underfloor loop against that temperature and tell you which can stay and which would need to be larger.
03
Where the outdoor unit stands, with regard to airflow, condensate drainage, sound towards neighbours and access for servicing. Then the pipe runs into the house, the hot water cylinder, and a buffer where the design calls for one.
04
Connecting the heat pump to the system you have: existing pipework, zones and controls, the hot water side and, where it is part of the design, an existing boiler kept as a second heat source.
Survey to handover
The second stage matters most. If the calculation says the house is not ready for a heat pump, you hear that before anything is ordered.
Building fabric, room sizes, existing emitters and pipe sizes, the electrical supply, possible positions for the outdoor unit and space indoors for a cylinder.
We calculate the heat demand and tell you plainly whether a heat pump suits the house as it is, what would have to change first, or whether another approach makes more sense.
Unit output, cylinder, emitter changes, pipe routes, controls and electrical requirements, with a clear line between what we do and what belongs to other trades.
Base and mounting for the outdoor unit, pipework, cylinder, any radiator or underfloor changes, and wiring of the controls.
The system is flushed, filled and vented, flow rates are set, and the weather compensation curve is given a starting point. Then the system is run and observed.
How to use the controls, what normal operation looks like (radiators that feel warm rather than hot, and longer running periods) and what routine care the system needs.
Before the survey
Questions
Sometimes with all of them, sometimes with most. It depends on the heat loss of each room and the size of the radiator in it. We check each one and list those that would need changing.
We do not quote savings figures. Running costs depend on the building, on how the system is set up and used, and on energy prices, which nobody can promise. What we can do is size and set up the system so that it runs the way it should.
That is what the survey and the heat loss calculation are for. If the house needs other work first, or if a heat pump is not a sensible choice for it, we say so.
A system can be designed that way. The two heat sources need a clear control strategy so that they do not work against each other, and that is settled at design stage.
Outside, a unit with free airflow around it. Inside, usually a hot water cylinder plus some pipework and controls. The exact space depends on the equipment chosen, and we mark it out during the survey.
In most designs, yes: the heat pump heats a cylinder as well as the heating circuit. The cylinder is sized from how much hot water the household uses.
Next step
Tell us about the house and the heating you have today. An honest answer about suitability comes before any talk of equipment.